Emergency Lighting Overview

Emergency lighting is the least-inspected life safety system in most buildings and the one most likely to fail when it matters. Batteries degrade quietly, luminaires get removed during refurbishment, and the logbook stops being filled in.

Recall runs the full cycle: monthly function testing, annual three-hour duration testing, luminaire replacement and design work where coverage does not meet the standard. Every test is recorded against the individual luminaire, not just the building.

Where a building has changed — new partitions, altered escape routes, a change of use — we re-survey coverage against BS 5266 rather than testing lights that are now in the wrong place.

02

Compliance

Emergency lighting compliance rests on two things: adequate coverage for the escape routes as they exist today, and evidence that the system has been tested on schedule.

Visual inspection

Boards, accessories, containment, signs of overheating, damage or unsafe modification.

Dead & live testing

Continuity, insulation resistance, polarity, earth fault loop impedance and RCD operation.

Coded observations

Every finding coded C1, C2, C3 or FI with a plain-English explanation of the risk.

Schedule of results

Full test results per circuit, so next inspection can compare against a baseline.

Test
Frequency
What it proves
Function test
Monthly
Lamp, driver and changeover circuitry operate on mains failure
Duration test
Annually
Battery sustains full rated output for three hours
Visual inspection
Monthly
Fittings present, undamaged, unobstructed and clean
Design review
On building change
Coverage still matches escape routes and room use

Testing must not leave the premises without emergency cover — duration tests are timed so batteries can recharge before occupancy.

The Regulatory Reform (Fire Safety) Order 2005 requires emergency routes and exits to be illuminated in the event of failure of normal lighting, and requires the responsible person to keep the system maintained in efficient working order and in good repair.
RRO 2005
BS 5266-1
BS EN 1838
BS EN 50172
03

Testing & Maintenance

Monthly function test

Brief simulated mains failure confirming each luminaire and exit sign illuminates.

Annual duration test

Full three-hour discharge proving batteries hold up for the rated period.

Luminaire schedule

Every fitting located, numbered and tracked so failures are traceable year to year.

Design & coverage survey

Escape route, open area and high-risk task lighting assessed against BS 5266 and EN 1838.

Replacement & repair

Failed batteries, drivers and fittings replaced with like-for-like or upgraded LED.

Compliance logbook

Digital records kept in the format a fire officer or insurer expects to see.

04

How it works

1

Asset survey

We locate and number every luminaire and exit sign, and record type and battery age.

First visit

2

Coverage assessment

Escape routes, changes of level, stairs, final exits and high-risk areas checked for compliance.

First visit

3

Testing programme

Monthly function and annual duration tests scheduled into your compliance calendar.

Ongoing

4

Remedial works

Failures replaced and coverage gaps quoted with drawings where new fittings are needed.

By agreement
05

Why choose Recall

Frequently asked

Can staff do the monthly tests themselves?

Yes, and many do — the standard allows a competent person on site to run function tests and record them. We supply the logbook and take the annual duration test, or run both if you would rather not own it.

Mains supply to the fittings is isolated and the batteries run the luminaires for the full three hours. We return to confirm which fittings survived and restore the supply.

Not every room. Escape routes, stairs, changes of level, final exits, plant rooms, lifts, toilets over a certain size and high-risk task areas are the usual scope — the survey confirms it.

Typically three to five years. We track battery age per fitting so replacements can be budgeted rather than discovered.