Standard

CIBSE LG7 / BS EN 12464

Typical saving

50–70% on lighting load

Payback

Usually 2–4 years

Warranty

5 years on most fittings

On this page
Talk to an engineer

01726 839333

Mon–Fri 8am–5pm. 24/7 emergency line out of hours.

01

Lighting Solutions

Lighting is usually the largest single electrical load in a commercial building and the one most likely to be twenty years out of date. Replacing fluorescent and halogen with LED typically removes half to two-thirds of that load, and removes the lamp-changing visits with it.

The saving is only part of it. Lux levels, glare and colour rendering determine whether a space is comfortable to work, learn, treat patients or sell in — and old installations are frequently both wasteful and badly lit at the same time.

We survey the existing installation, measure actual lux levels against the CIBSE recommendation for each task, and design a replacement scheme rather than swapping fitting for fitting. In practice that often means fewer luminaires, better placed, with better distribution.

Controls are where the remaining savings sit. Presence detection in intermittently occupied spaces, daylight dimming near glazing, and time scheduling on external and circulation lighting routinely take another quarter off consumption without anyone noticing a change.

Every proposal is modelled: existing load and hours, proposed load and hours, expected saving and simple payback. If the numbers do not work on a particular area we will say so rather than including it to inflate the project.

Fixed wiring inspection at a distribution board
02

Control Systems

Lighting survey

Existing fittings, wattages, hours of use and measured lux levels recorded per area.

Scheme design

Layout designed to CIBSE recommendations for each task, not simply matched to existing positions.

LED supply & install

Commercial-grade luminaires with warranties, installed and tested by our own electricians.

Presence & daylight control

Detection and dimming in stores, corridors, toilets, offices and perimeter zones.

Emergency provision

Emergency luminaires integrated into the new scheme and brought onto the test regime.

Energy modelling

Before and after load, projected saving and simple payback, in writing.

03

Installation & Energy

1

Survey and measure

Existing installation recorded and lux levels measured against task requirements.

Week 1

2

Design and model

Scheme layout, control strategy and an energy model with projected payback.

Week 1–2

3

Sample area

On larger schemes we light one area first so you can see it before committing.

Optional

4

Install and commission

Phased installation, controls commissioned and set up, old fittings removed and recycled.

Per programme
04

Where controls pay back fastest

Space
Control strategy
Typical saving
Toilets & stores
Presence detection, absence off
60–80%
Corridors & stairs
Presence with dimmed standby
40–60%
Perimeter offices
Daylight dimming
25–40%
External & car park
Photocell plus time schedule
20–35%

Savings are against the same LED fitting without controls — they stack on top of the LED saving itself.

05

Your legal duty

Lighting installations must comply with BS 7671, and workplace lighting must be suitable and sufficient under the Workplace (Health, Safety and Welfare) Regulations 1992. Emergency lighting integrated into a new scheme remains subject to BS 5266-1.
BS 7671
BS EN 12464-1
CIBSE LG7
Workplace Regs 1992
06

Why choose Recall

Frequently asked

Can we just replace the tubes with LED versions?

Sometimes, and it is the cheapest option. But retrofit tubes in old fittings keep the old optics and old positions, so you get the energy saving without the lighting improvement — and warranties are shorter.

Low. It is usually done area by area outside occupied hours, with each area finished and working before we move on.

Yes. Areas with very low hours of use rarely justify replacement on energy grounds alone, and we will flag those as maintenance-driven rather than savings-driven.

Only if they are set up badly — detection that times out too fast is the usual complaint. We commission on site and revisit settings after a few weeks of real use.

Still running fluorescent lighting?

A survey will tell you the saving, the payback and what the space would actually look like.